Customization: | Available |
---|---|
Material: | POM |
Media: | Gas |
Still deciding? Get samples of US$ 10/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ATEX Classification: II 2G Ex h IIC T4 Gb GB3836.1,GB3836.4,GB3836.8 Electrical safety: EN ISO 80079-36:2016 /EN ISO 80079-37:2016 ROSH: 2011/65/EU Flow-rate Range: 0~60m³/h GM Application: G6~G40 Operating Humidity :≤93% Operating Pressure: 0~30Kpa/300mbar Pressure Drop: ≤90pa Nominal Voltage: DC 2.5V~6V Winding Resistance: 21±2Ω(23ºC±2ºC) Operating Average Current:≤80mA Peak Current: ≤150mA(DC 2.5V) Valve Opening time :≤5S(DC4V) Valve Closing time: ≤5S(DC4V) Internal Leakage: ≤0.1L/h (P=1.8~15Kpa) External Leakage: NO Leakage (P=1.8~15Kpa) Relative Humidity: 93%RH Operating Temp.: -20ºC~+50ºC Storage Temp.: -25ºC~+60ºC Life Time: ≥5000 cycles(≈10 Years) Main Materials : POM, NBR | ATEX Classification: II 2G Ex h IIC T4 Gb GB3836.1,GB3836.4,GB3836.8 Electrical safety: EN ISO 80079-36:2016 /EN ISO 80079-37:2016 ROSH: 2011/65/EU Flow-rate Range: 0~60m³/h GM Application: G6~G40 Operating Humidity :≤93% Operating Pressure: 0~30Kpa/300mbar Pressure Drop: ≤90pa Nominal Voltage: DC 2.5V~6V Winding Resistance: 21±2Ω(23ºC±2ºC) Operating Average Current:≤80mA Peak Current: ≤150mA(DC 2.5V) Valve Opening time :≤5S(DC4V) Valve Closing time: ≤5S(DC4V) Internal Leakage: ≤0.1L/h (P=1.8~15Kpa) External Leakage: NO Leakage (P=1.8~15Kpa) Relative Humidity: 93%RH Operating Temp.: -20ºC~+50ºC Storage Temp.: -25ºC~+60ºC Life Time: ≥5000 cycles(≈10 Years) Main Materials : POM, NBR |
Flow-rate Range: 0.016~6m³/h
Working Pressure Range: 0~15kPa
Relative Humidity: ≤93%RH
Operating Temperature: -20°C~+50°C
Storage Temperature: -25°C~+60°C
Motor resistance: 21±2Ω(23±2ºC, 100Hz)
Motor Inductance: 14±1.2mH(23±2ºC, 100Hz)
Pressure Loss: ≤50Pa(6m³/h)
Internal Leakage: < 0.04L/h (at1.8~15kPa)
Durability: ≤15 Years (No Fault or Damage after Continuous Working 10000 times)
Operating Voltage: DC2.5~5.5V
Switching Valve Average Current: ≤80mA(+23°C+/-2°C DC3.6V)
≤80mA(-20°C DC3.6V)
Max. Working current: ≤1500mA(-20°C DC3.6V)
Opening Valve Time: ≤1.5S(-20°C DC3.6V ≤1.5S)
(+23°C+/-2°C DC3.6V ≤1.0S)
Closing Valve Time: ≤1.5S(-20°C DC3.6V ≤1.5S)
(+23°C+/-2°C DC3.6V ≤1.0S)
Peak Current(Motor Start-up): ≤400mA (DC5.5V)
ATEX classification acc. To ISO EN 80079-36:2016: II 2G Ex h IIC T4 Gb
Gas Meter Application: G1.6~G4 Gas Meters
Structural Support: Materials are POM, Valve Seal is NBR
Service Fluid: Natural Gas/LPG
Q1: How long is your delivery time?
A:Delivery time is depends on the total quantity of order. Normally, sample can be delivered within 15 days.
Q2: Do you provide samples? Is it free or extra?
A:Yes, we could offer sample for free, but the clients has to pay for the shipping cost.
Q3: What is the MOQ of your products?
A:It normally is 1000pcs/PO of the products we already mass production. But mostly our products are customized for our customers.
Q4: Where is your factory?
A:Our factory located in Zhejiang province, we are close to Ningbo port.
Q5:What does your company need to submit a quotation?
A:After confirmed with customers on products design, we can offer mould quotation and unit price.
Q6:Why we do not have drawing here?
A:Valve always are customized to different customers. Because valves are designed according to Meter's space to assembly with .